新闻资讯PCBanner 新闻资讯wapBanner
首页 > Flow Meters' Diary > News of Flow Meter > 2 component plant gear flowmeter
Submit a message
  • Name*
  • Tel*
  • Email*
  • Content*
  •  

Friendship tips

    Shanghai JSN Micro Flow Meter CO.,LTD as a high-tech industrial products manufacturing and complete sets of product sales, R & D, production, processing and sales as one, with independent import and export rights of enterprises.
    The company's main flow meter, level meter, and pressure controller, temperature controller, analytical instruments and other various types of instrumentation. To solve all kinds of problems, and provide complete sales service for customers with professional technical point of view.
International service telephone
(86)021-57632436

2 component plant gear flowmeter

Date:2017-01-21 source:

  2 component plant gear flowmeter  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow MeterCO.,LTD is established in 2011, directly under Shanghaijurisdiction.Our factory is professional produce electromagnetic flow meter, Super Micro Liquid Flow Meter,Ovalgear flow meter ,Mass Flow Meter,Circle Spur Gear Flow Meter,Gear Pump,Gearmetering Pump etc. After decades of ups and downs, we have established adeep affection with electricity, chemical industry, petroleum, cement, sewage,steel, and environmental protection all over the country. Our factory, as anational key instrumentation production base, has received the ProvincialDepartment of Science and Technology. The leader attaches great importance to,and has received a lot of company leadership acclaim and full affirmation. Atthe same time was rated as high-tech enterprises in Shanghai, and passedIS09001 quality system certification.

 2 component plant gear flowmeter

2 component plant gear flowmeter

Onceupon a time, China"s manufacturing industry in the world"s processing plant hasalways been the "low quality" representative of the world. Inparticular, the Oval gear flow meter for automatic process control has theadvantages of large volume, large noise, small turndown ratio, , The use ofeasy to leak, instability and so on, leaving customers a headache is that manyproblems in the early stages of product does not appear, and in the event ofafter-sale is very troublesome, bothering money, these are domestic objectiveobjective existence of Oval gear flow meter Therefore, users buy Oval gear flowmeter is like buying lottery tickets, do not know sent to the installation siteOval gear flow meter is a blessing, in a sense, is a matter of course, whilethe base depth meter appeared to solve these problems in one fell swoop.

Base deep gear wheel flowmeter on the production of all caliberflowmeters, basically have stock inventory, which in itself shows that thecompany"s funds and sales are good, we dare to do inventory. Hee Oval gear flowmeter has two national inventions, In the process of production qualitycontrol, starting from the beginning of the procurement of raw materials, everyproduction and precision machining links careful examination, each of the Ovalgear flow meter factory must be continuous calibration test. Processinstallation ISO9001 quality management system strictly enforced, the producthas the CE, SGS and other EU certification. Our company has "the qualityof Germany, China"s manufacturing" as the slogan to create a world-classoval gear flow, real automation instrumentation industry Benchmarking business.

gear flowmeter

2 component plant gear flowmeter

The Ovalgear flow meter consists of a metering box and a pair of gears mounted in themetering box. It forms a sealed initial moon cavity with the upper and lowercover plates as a unit of calculation of the primary displacement. When themeasured liquid enters the flow meter through the pipe, The pressure differencegenerated at the outlet pushes a pair of gears to continuously rotate, and theliquid measured by the initial cavity is continuously delivered to the outlet.The product of the number of rotations of the gear and four times of eachdisplacement is the measured liquid flow rate. The total flowmeter is mainlycomposed of a housing, a counter, a gear and a coupling (magnetic coupling andaxial coupling).

 2 component plant gear flowmeter

2 component plant gear flowmeter

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


What are the precautions for the gear flow meter?

1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.

2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted

3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.

Share to: